Housing height
110 mm
Wide housing
36.6 mm
Deep housing
169.9 mm
Weight
800 g
Front panel
10 TE / 3HE
MT6E-D
Without front panel
MT6E-D/FPL
with front panel
GSM Phase 2+ Teleservices
TS11Telephony
TS12Emergency call
TS21: Short messages MT/PP
TS22: Short messages MO/PP
TS23: Short messages Cell broadcast CBM
GSM Phase 2+ Bearer Services
BS242.4 kbits T/NT, UID, 3.1 kHz, V110
BS254.8 kbits T/NT, UID, 3.1 kHz, V110
BS269.6 kbits T/NT, UDI, 3.1 kHz, V110
BS70GPRS transmission service
BS71EGPRS transmission service
Functional addressing
Call pre-selection and priority (eMLPP)
Location-dependent addressing
GSM-R operating frequencies
1710 to 1785 MHz / 1805 to 1880 MHz
Filtered LTE frequencies*
1775.3 to 1782.3 MHz / 1870.3 to 1877.3 MHz
ARFCN: 838 to 872
Transmission power
4 W (DCS Power Class 3)
Sensitivity
-102 dBm
HF filtering / blocking properties
Fulfils the railway-specific receiver requirements based on
ETSI TS 102 933 V 2.1.1
Protection class
IP20 according to EN 60529
Vibrations / shocks
according to EN 50155
EMC
in accordance with EN 50121-3-2 and EN 50155
Working temperature
-25 °C to 70 °C
Storage temperature
-40 °C to 85 °C
Maximum change in ambient temperature
± 1 °C/min
Relative humidity
according to EN 50155
Operating voltages
12 VDC (11.7 to 12.9 V)
5 VDC (4.8 to 5.25 V)
Average power consumption
6 W at 12 VDC
5 W at 5 VDC
Maximum power consumption
0.5 A at 12 VDC
1 A at 5 VDC
Power consumption in standby mode (idle mode)
0.070 A at 12 VDC
0.175 A at 5 VDC
Power consumption (total)
1.75 W (stand-by)
*Frequencies/channels protected by SAW filter bank