The MT5E is a GSM Phase 2+ radio module with GSM-R and ASCI extensions. The module is operated within the GSM-R frequency range with a maximum transmission power of 8W (GSM Power Class 2) and is equipped for the ER-GSM frequency band extension. The MT5E supports GPRS Multi-Slot Class 10 with Class B, C, CS operating modes (optional). The protocol software complies with the R97/R99 GSM specification and is approved in accordance with GCF3.14.
Interface configuration
Software update
Voice and data connections (circuit/packet) can be established.
Optional tracking of GSM-R protocol signalling (trace)
Software in accordance with GSM Rel. 04 is also available.
Special filter banks in the GSM-R module
Intelligent control via software
Adaptation of the protocol stack (Layer 1) for operating the filter bank depending on the BCCH information (Broadcast Control Channel)
Compliance with ETSI standard TS 102 933-1 V2.1.1 & TS 102 933-2 V2.1.1 for improved GSM-R receivers
You will find a level table of the unwanted signals in the data sheet, which you can download here. download below can.
Enquire nowHeight
Housing: 110 mm
Front panel: 3 U
Width
Housing: 36.6 mm
Front panel: 10 TE
Depth
169.9 mm
Weight
750 g
GSM Phase 2+ Teleservices
TS11Telephony
TS12Emergency call
TS21: Short messages MT/PP
TS22: Short messages MO/PP
TS23: Short messages Cell broadcast CBM
TS62Automatic fax group 3
TS91: Voice group calls
TS92: Voice collective calls
GSM Phase 2+ Bearer Services
BS242.4 kbits T/NT, UID, 3.1 kHz, V110
BS254.8 kbits T/NT, UID, 3.1 kHz, V110
BS269.6 kbits T/NT, UDI, 3.1 kHz, V110
BS70GPRS transmission service
Functional addressing
Call pre-selection and priority (eMLPP)
Location-dependent addressing
Railway emergency call (REC) / extended emergency call (eREC)
Operating frequencies
R-GSM: 876 ... 915 MHz / 921 ... 960 MHz
ER-GSM: 873 ... 915 MHz / 918 ... 960 MHz
Transmission power
8 W (GSM class 2)
Sensitivity
-104 dBm
Protection class
IP20 according to EN 60529
Vibrations / shocks
according to EN 50155
EMC
in accordance with EN 50121-3-2 and EN 50155
Working temperature
-25 °C to 70 °C
Storage temperature
-40 °C to 85 °C
Maximum change in ambient temperature
± 1 °C/min
Relative humidity
according to EN 50155
Fire protection
in accordance with EN 45545-2:2020-10 and EN 45545-5
Input voltage
12 VDC
5 VDC
Power consumption
(according to voltage)
max. 6 W*
max. 4 W
Power supply
Data / Service (TTL)
Reset
Analogue audio in/out
GS01
All SW versions can be used
GS02
Can be used from SW version 5.00.06
* 8 W transmission power, for single TX slot