EDOR 5E
ETCS module

Modular solution for ETCS applications

The EDOR-5E modules can be equipped with or without a data logger (EDOR-5E or EDOR-5E/DLOG). The data logger is intended for collecting trace data from the integrated MT5-E radio module within the RIU-ETCS.

One to four EDOR-5E modules are mounted in an approved and certified 19“ standard rack as required The radio module uses a Release 04 GSM standard, connection-orientated and packet-orientated data are possible. The EDOR-5E fulfils the latest specification for improved receiver parameters ETSI TS 102 933 V2.1.1.

ETCS

On the initiative of the EU, the European railways have introduced ETCS (European Train Control System) as a standardised train control system. This standard is intended to ensure European interoperability with a high level of reliability and safety in rail transport. In addition to many other operational and technical advantages, ETCS enables economical operation, higher speeds and better route utilisation.

ETCS Level 1 is realised by discontinuous track/vehicle communication using Euro balises or track loops and the existing signalling systems. Track signalling is not required for Levels 2 and 3. Train control is realised via continuous GSM-R data communication between the control centre and the vehicle.

The train equipment requires for ETCS Level 2 and 3 at least two radio subsystems for GSM-R data independent of the GSM-R voice communication system.

Enquire now

Technical data

Dimensions & weight

Height

3U, 129 mm

Width

86 mm

Depth

785 mm

Weight

1.5 kg

Power supply

Nominal voltage range

24 V to 110 V

Tolerances

16.8 to 137.5 V

Type

floating

Stand-by power (idle)

3,5 W

Maximum power GSM mode

10,3 W

GPRS mode

15,6 W

Connection

Phoenix PSC 1.5 / 5-M-PE protection class 1

Environmental conditions

Working temperature range

-25 to +70°C (EN 50155) T3

Storage temperature range

-40 to +85°C

Data interface

User (DATA)

V.24 / V.11 (RS422)

Service

V.24 / V.28 (RS232)

Radio interface

Frequency range

ER-GSM: TX 873-915 MHz / RX 918-960 MHz
ARFCN: 940-1023, 0-124

Transmission power

8 W -/+ 2db GSM class 2

Reference sensitivity

-104 dBm typical

Antenna connection

TNC socket, 50 Ohm

Multi-slot class 10

CS-1, CS-2, CS-3, CS-4, MCS5-MCS9

GSM transmission service

according to GSM 02.02 (ETS 300 501)

transparent according to GSM 04.22 (ETS 300 053)

BS24 asynchronous data 2.4 kbit/s

BS25 asynchronous data 4.8 kbit/s

BS26 asynchronous data 9.6 kbit/s

BS70 GPRS | E-GPRS (EDGE)

Additional services

CLIP, CoLP, UUS1, eMLPP

others: OTDI, cOTDI, USSD, CLIR, CoLR, CFU, CFB, CFNRy, CFNRc, CW, HOLD, MPTY, CUG, AoCI, AoCC, BAOC, BOIC, BOIC-exHC, BAIC, BAIC-Roam

Additional Funkwerk-specific functions, e.g. speeding up the network search

Data logger interface

GPS / Trace / ODO

3 x 5-pin M9 connector

Ethernet connection

4-pin M12 plug

Miscellaneous

Internal ARM-based processor system

SW based on Linux operating system

2 GB internal data memory in the data logger

Software

GS00

All SW versions can be used

GS01

Can be used from software version EDOR 1.3.0 08.34.01

Enquire now

Product folder

magnifier