CR26P IP54 train radio system
MESA26 central unit

Protection class IP54

The CR26P central unit is a train radio device for GSM-R radio networks and ensures operational communication for the train driver. The CR26P can be expanded with an ARM26P/x analogue radio device to create a dual-mode train radio device for voice radio/shunting radio and data radio applications. The CR26P fulfils the Protection class IP54. It fulfils the European requirements for use in rail vehicles.

The CR26P is the main component of a digital train radio system. It contains the digital transmitter and receiver unit, the control unit, the interface modules for connecting external devices and the internal power supply. The CON26 module forms the central control unit. It controls the radio connection, regulates the call priorities, controls the control units, the module for the digital train radio, the data applications and the interface modules. Software, configuration and diagnostic data for the CR26P can be read out and updated both via the LAN interface and via the air interface.

The terminal device operates in accordance with GSM 05.05 Phase 2+ and in the extended GSM / GSM-R frequency range in the following frequencies:

Transmission frequency range: 873 to 915 MHz

Reception frequency range: 918 to 960 MHz

Components

The CR26P realises the EIRENE functionality in conjunction with the control units, handsets and loudspeakers. The standard version is equipped with the following components:

2 Assemblies IFS each with 2 serial interfaces for data transmission

Assembly group UIC26 for connection to the train-internal through line in accordance with UIC 568 (PA / Intercom)

Assembly group SW26 Ethernet switch with 3 connections

Assembly group DIO26 with 4 digital inputs and outputs each

Enquire now

Highlights

fulfils protection class IP54
Universal system architecture
Uniform and standardised interfaces and assemblies
Fast and efficient repair
Low training requirements for maintenance personnel

Technical data

Dimensions & weight

Construction method

Enclosed housing (IP54)

Height

132 mm

Width

345 mm

Depth

195 mm

Weight

max. 8 kg

Power supply

Input voltage

24, 36, 48, 72, 110 VDC via external converter

Tolerances

according to DIN EN 50155

Interruption

according to DIN EN 50155, class S1 (no interruption)

Maximum input power

Nominal 240 W (calculated)

Maximum power consumption

16 A (at nominal voltage 48 V)

Environmental conditions

Protection class

IP54 according to DIN EN 60529

Vibrations and shocks

according to DIN EN 50155

EMC

in accordance with DIN EN 50121-3-2 and DIN EN 50155

Notes

Labelling scheme

CR26P (nominal input voltage)

System designation

MESA26: including central unit (CR26P), control panel(s) MMIC-x, MMIT, handset(s), loudspeaker and cable

Climatic conditions

Operating temperature

-25 °C to +70 °C (EN 50155 T3)

Storage temperature

-40 °C to +70 °C (in original packaging)

Maximum gradient

± 1 °C/min Ambient temperature

Maximum humidity

75 % annual average

Relative humidity

95 % on a maximum of 30 days per year

Height and pressure fluctuations

-100 m to 1800 m above sea level

Interfaces

MMIC control panel

2 x M12 round plug connector

Antenna connection

TNC socket GSM-R; TNC socket GPS (option)

Through conductor UIC

25-pin D-Sub socket

Digital input and output

25-pin D-Sub socket

RS422

2 x 26-pin HD-D-Sub socket ; 2 x 15-pin HD-Sub socket

Service, diagnosis

Circular connector M12 socket

IFE extension interface

Circular connector M12 socket

Locomotive identification module NL

15-pin D-Sub socket

Other

Voltage connection, protective conductor connection

Enquire now

Product folder

magnifierchevron-right