RIU-ETCS 5E
Radio data transmission device for ETCS

Up to 4 completely independent radio units

RIU-ETCS - Funkwerk's mobile solution for ETCS applications consists in the standard version of fully independent radio units EDOR-5E with integrated state-of-the-art GSM-R mobile radio module MT5-E (8 Watt) and the wide-range power supply (24 to 110 V on-board voltage). The EDOR-5E fulfils the latest specification for improved receiver parameters ETSI TS 102 933 V2.1.1.

EDOR 5E modules

The EDOR-5E modules can be equipped with or without a data logger (EDOR-5E or EDOR-5E/DLOG). The data logger is intended for the collection of trace data from the integrated MT5-E radio module within the RIU-ETCS. One to four EDOR-5E modules are mounted in an approved and certified 19“ standard rack as required. The radio module uses a Release 04 GSM standard, connection-orientated and packet-orientated data are possible.

ETCS

On the initiative of the EU, the European railways have introduced ETCS (European Train Control System) as a standardised train control system. This standard is intended to ensure European interoperability with a high level of reliability and safety in rail transport. In addition to many other operational and technical advantages, ETCS enables economical operation, higher speeds and better route utilisation.

ETCS Level 1 is realised by discontinuous track/vehicle communication using Euro balises or track loops and the existing signalling systems. Track signalling is not required for Levels 2 and 3. Train control is realised via continuous GSM-R data communication between the control centre and the vehicle.

The train equipment requires for ETCS Level 2 and 3 at least two radio subsystems for GSM-R data independent of the GSM-R voice communication system.

Enquire now

Technical data

Dimensions & weight

Height

132 mm (3U)

Width

483 mm

Depth

190 mm

Weight

7.5 kg (maximum load)

Power supply

Nominal voltage range

24 V to 110 V

Tolerances

16.8 to 137.5 V

Type

floating

Stand-by power (idle)

3.5 W / set

Maximum power GSM mode

10.3 W / set

GPRS mode

15.6 W / set

Connection

Phoenix PSC 1.5 / 5-M-PE protection class 1

Environmental conditions

Working temperature

-25 to +70°C (EN 50155) T3

Storage temperature

-40 to +85°C

Data interface

User (DATA)

V.24 / V.11 (RS422)

Service

V.24 / V.28 (RS232)

Radio interface

Frequency range

ER-GSM: TX 873-915 MHz / RX 918-960 MHz
ARFCN: 940-1023, 0-124

Transmission power

8 W -2 /+2 dB GSM class 2

Reference sensitivity

-104 dBm typical

Antenna connection

TNC socket, 50 Ohm

Multi-slot class 10

CS-1, CS-2, CS-3, CS-4, MCS5-MCS9

Configuration

with data logger

RIU-ETCS 5E/1MT/1DLOG => 1 module EDOR-5E/DLOG
RIU-ETCS 5E/2MT/2DLOG => 2 modules EDOR-5E/DLOG
RIU-ETCS 5E/3MT/3DLOG => 3 modules EDOR-5E/DLOG
RIU-ETCS 5E/4MT/4DLOG => 4 modules EDOR-5E/DLOG

without data logger

RIU-ETCS 5E/1MT => 1 module EDOR-5E
RIU-ETCS 5E/2MT => 2 modules EDOR-5E
RIU-ETCS 5E/3MT => 3 modules EDOR-5E
RIU-ETCS 5E/4MT => 4 modules EDOR-5E

GSM transmission service

according to GSM 02.02 (ETS 300 501)

transparent according to GSM 04.22 (ETS 300 053)

BS24 asynchronous data 2.4 kbit/s

BS25 asynchronous data 4.8 kbit/s

BS26 asynchronous data 9.6 kbit/s

BS70 GPRS | E-GPRS (EDGE)

Additional services

CLIP, CoLP, UUS1, eMLPP

others: OTDI, cOTDI, USSD, CLIR, CoLR, CFU, CFB, CFNRy, CFNRc, CW, HOLD, MPTY, CUG, AoCI, AoCC, BAOC, BOIC, BOIC-exHC, BAIC, BAIC-Roam

Additional Funkwerk-specific functions, e.g. speeding up the network search

Data logger interface

GPS / Trace / ODO

3 x 5-pin M9 connector

Ethernet connection

4-pin M12 plug

Miscellaneous

Internal ARM-based processor system

Software based on Linux operating system

2 GB internal data memory in the data logger