The EDOR-5E modules can be equipped with or without a data logger (EDOR-5E or EDOR-5E/DLOG). The data logger is intended for collecting trace data from the integrated MT5-E radio module within the RIU-ETCS.
One to four EDOR-5E modules are mounted in an approved and certified 19“ standard rack as required The radio module uses a Release 04 GSM standard, connection-orientated and packet-orientated data are possible. The EDOR-5E fulfils the latest specification for improved receiver parameters ETSI TS 102 933 V2.1.1.
On the initiative of the EU, the European railways have introduced ETCS (European Train Control System) as a standardised train control system. This standard is intended to ensure European interoperability with a high level of reliability and safety in rail transport. In addition to many other operational and technical advantages, ETCS enables economical operation, higher speeds and better route utilisation.
ETCS Level 1 is realised by discontinuous track/vehicle communication using Euro balises or track loops and the existing signalling systems. Track signalling is not required for Levels 2 and 3. Train control is realised via continuous GSM-R data communication between the control centre and the vehicle.
The train equipment requires for ETCS Level 2 and 3 at least two radio subsystems for GSM-R data independent of the GSM-R voice communication system.
Enquire nowHeight
3U, 129 mm
Width
86 mm
Depth
785 mm
Weight
1.5 kg
Nominal voltage range
24 V to 110 V
Tolerances
16.8 to 137.5 V
Type
floating
Stand-by power (idle)
3,5 W
Maximum power GSM mode
10,3 W
GPRS mode
15,6 W
Connection
Phoenix PSC 1.5 / 5-M-PE protection class 1
Working temperature range
-25 to +70°C (EN 50155) T3
Storage temperature range
-40 to +85°C
User (DATA)
V.24 / V.11 (RS422)
Service
V.24 / V.28 (RS232)
Frequency range
ER-GSM: TX 873-915 MHz / RX 918-960 MHz
ARFCN: 940-1023, 0-124
Transmission power
8 W -/+ 2db GSM class 2
Reference sensitivity
-104 dBm typical
Antenna connection
TNC socket, 50 Ohm
Multi-slot class 10
CS-1, CS-2, CS-3, CS-4, MCS5-MCS9
according to GSM 02.02 (ETS 300 501)
transparent according to GSM 04.22 (ETS 300 053)
BS24 asynchronous data 2.4 kbit/s
BS25 asynchronous data 4.8 kbit/s
BS26 asynchronous data 9.6 kbit/s
BS70 GPRS | E-GPRS (EDGE)
CLIP, CoLP, UUS1, eMLPP
others: OTDI, cOTDI, USSD, CLIR, CoLR, CFU, CFB, CFNRy, CFNRc, CW, HOLD, MPTY, CUG, AoCI, AoCC, BAOC, BOIC, BOIC-exHC, BAIC, BAIC-Roam
Additional Funkwerk-specific functions, e.g. speeding up the network search
GPS / Trace / ODO
3 x 5-pin M9 connector
Ethernet connection
4-pin M12 plug
Internal ARM-based processor system
SW based on Linux operating system
2 GB internal data memory in the data logger
GS00
All SW versions can be used
GS01
Can be used from software version EDOR 1.3.0 08.34.01